Free shipping on all orders over $99!*(Click here to see exclusions)

0

Your Cart is Empty

New Image Gallery

GHL USA

KH Director/ Doser 2.1 Slave (4 channels) - GHL USA

Color
Black
White
This item is a Special Order. Special Orders are only refundable to store credit. Once your order is placed, we will contact you to let you know the estimated timeline for shipping.

IMPORTANT NOTE: KH Director requires 3 dosing pumps to operate! If you do not have 3 unused pumps, we recommend purchasing a KHD/ Doser 2.1 set.

 

***Shown item is for KH Director and GHL Doser 2.1 SLAVE (4 channel set). This combo requires a Doser 2.1 SA or ProfiLux 3 or 4 to operate.

GHL KH Director – Monitor, maintain, and control Alkalinity with ease

The upkeep of Alkalinity is the most important aspect of reef keeping. If you’re looking to achieve exceptional coral growth, Alkalinity testing is a must!

The KH Director is the result of more than 2 years of research and development into the automated Alkalinity monitoring and control department. As always, we’ve stuck to our fundamental belief in high quality and exceptional reliability to bring you a product that is built to last. Featuring a patent pending design, KHD utilizes lab grade quality test standards to provide precise results every time. KHD is built to provide aquarium hobbyists and professionals with a safe and reliable Alkalinity control product which presents great value, functionality, and practicality.

Automated Alkalinity monitoring and control

KH Director uses a modified pH probe to provide KH values. In terms of the KH test process, the 3 blue adapters on the KHD each connect to an available GHL Doser 2 or 2.1 dosing unit. One pump is used to feed tank water into the KHD. The second pump feeds the KHD with reagent fluid. The third pump extracts the test sample and used reagent fluid after a completed test, then dispenses it into a waste bin.

As tests occur, the 3 pumps automatically perform their assigned tasks and report the results onto a viewable data logging chart. This data is then viewable on myGHL, ProfiLux Touch, ProfiLux display, and additional external display unit.

Lab grade KH measurement accuracy

Measure your Alkalinity with lab-grade accuracy. With only a 100 ml water sample, KH Director® can provide measurement values with 0.1 ° dKH accuracy.

Extreme efficiency and cost-effectiveness

For the KH Director it was especially important to consider these costs and develop a highly-efficient, cost-effective product. A single 1000ml bottle of reagent can last for up to 3 months when testing is performed 4x per day at a KH value of 8.  The pH electrode used by the KH Director was specially designed for KH measurement and has an average lifespan of 1 - 2 years.

Seamless integration w/ GHL system

Through the use of the PAB (ProfiLux Aquatic Bus) connection, KH Director® seamlessly integrates into the modular GHL aquarium system. The PAB connection ensures interference free communication with other GHL PAB-devices such as the GHL Doser 2.1 or the ProfiLux® 4.

Backwards compatibility

Even the ProfiLux 3 / 3.1 and GHL Doser 2.0 will be compatible with the KH Director.

Customer Reviews
0.0 Based on 0 Reviews
5 ★
0% 
0
4 ★
0% 
0
3 ★
0% 
0
2 ★
0% 
0
1 ★
0% 
0
Write a Review Ask a Question

Thank you for submitting a review!

Your input is very much appreciated. Share it with your friends so they can enjoy it too!

Filter Reviews:

×
Welcome Newcomer
x